LILIN Navigator with ANPR configured but no ANPR data shown in logs

If you are using the LILIN Navigator software and have installed the ANPR software correctly you must ensure you have configured the 'Alarm Management' correctly within the Navigator software.

Within the alarm management's 'Alarm Input' section you will see an 'ANPR Detection' check box, ensure this is checked, you will also need to ensure something is also checked in the 'Alarm Output' section.

 

Failure to check an alarm output trigger will result in the ANPR not logging any information in the event/data log, however you will still get the motion alarm trigger displayed on the camera image. It is recommended to select the 'Pre-alarm Record' and 'Post alarm Record'.